Product Safety Report: Lithium Battery Charger szYB-100W-42V2A (2304-0144)

Reference: 2304-0144

Product: N/A

Hazard: The product presents a serious risk of electric shock as it failed the electric strength test. The insulation between the input and output circuits broke down when a 2.92 kV test voltage was applied between the circuits. The plug did not comply with BSEN 1361-1 and the fuse did not comply with BS1362. The fuse had not been supplied with any granular filler. The filler is required to ensure the safe operation of the fuse under fault conditions.

Corrective Action: The import has been rejected at the border and destroyed.

PDF: Download